    250KVA-13V/11.5V-2 Welding Transformer

    250KVA-13V/11.5V-2 Welding Transformer

    Contact Us
  • ×
    300KVA-13V/11V-2 Welding Transformer

    300KVA-13V/11V-2 Welding Transformer

    Power source voltage (U1) 380V
    Secondary no-load voltage (U20) 13V/11V
    Power at 10% duty cycle (S10) 435KVA
    Power at 20% duty cycle (S20) 300KVA
    Power at 100% duty cycle (SP) 135KVA
    100% load output current (IP) 11000A
    Maximum short-circuit current for 500mm(L) × 300mm(H) circuit /
    Maximum short-circuit current for 1000mm(L) × 300mm(H) circuit /
    Cooling fluid flow rate Q 10L/min
    Insulation class F
    Protection grade Class II
    Weight 360KG
    Contact Us
  • ×
    450KVA-13V/15V-2 Welding Transformer

    450KVA-13V/15V-2 Welding Transformer

    Power source(U1) 380V
    Secondary no-load voltage (U20) 13V/15V
    Duty cycle 20%
    Power at 10% duty cycle (S10) 645KVA
    Power at 20% duty cycle(S20) 450KVA
    Power at 100% duty cycle(SP) 200KVA
    100% load current output(IP) 15500A
    Flow of cooling water Q 10L/min
    Insulation class F
    Protective grade II
    Weight 400KG
    Contact Us
  • ×
    630KVA-14V/16V-2 Welding Transformer

    630KVA-14V/16V-2 Welding Transformer

    Power source voltage (U1) 380V
    Secondary no-load voltage (U20) 14V/16V
    Power at 10% duty cycle (S10) 800KVA
    Power at 20% duty cycle (S20) 630KVA
    Power at 100% duty cycle (SP) 250KVA
    100% load output current (IP) 20000A
    Maximum short-circuit current for 500mm(L) × 300mm(H) circuit /
    Maximum short-circuit current for 1000mm(L) × 300mm(H) circuit /
    Cooling fluid flow rate Q 10L/min
    Insulation class F
    Protection grade Class II
    Weight 450KG
    Contact Us
  • ×
    MF220-46T Welding Transformer

    MF220-46T Welding Transformer

    Power source(U1N) 1000HZ/500V
    Secondary unload voltage(U20) 10.9V
    Power/current at 10% duty cycle(ON 200ms and OFF 1800ms) 320KVA/30KA
    Power/current at 20% duty cycle(ON 400ms and OFF 1600ms) 220KVA/20KA
    Power/current at 50% duty cycle(ON 1000ms and OFF 1000ms) 160KVA/14.7KA
    Power/current at 100% duty cycle 87KVA/8KA
    Maximum short-circuit current 50KA
    Flow of cooling water Q ≥2×8L/min
    Pressure difference of cooling water△P ≥0.15Mpa
    Insulation class H
    Protective grade IP30
    Weight 29KG
    Executive Standard GB/T25301-2021/ISO5826:2014
    Contact Us
  • ×
    MF180-54T Welding Transformer

    MF180-54T Welding Transformer

    Power source(U1N) 1000HZ/500V
    Secondary unload voltage(U20) 9.3V
    Power/current at 10% duty cycle(ON 200ms and OFF 1800ms) 280KVA/30KA
    Power/current at 20% duty cycle(ON 400ms and OFF 1600ms) 180KVA/20KA
    Power/current at 50% duty cycle(ON 1000ms and OFF 1000ms) 125KVA/13.5KA
    Power/current at 100% duty cycle 75KVA/8KA
    Maximum short-circuit current 45KA
    Flow of cooling water Q ≥2×8L/min
    Pressure difference of cooling water△P ≥0.15Mpa
    Insulation class H
    Protective grade IP30
    Weight 28KG
    Executive Standard GB/T25301-2021ISO5826:2014
    Contact Us
  • ×
    MF130-60T Welding Transformer

    MF130-60T Welding Transformer

    Power source(U1N) 1000HZ/500V
    Secondary unload voltage(U20) 8.3V
    Power/current at 10% duty cycle(ON 200ms and OFF 1800ms) 200KVA/24KA
    Power/current at 20% duty cycle(ON 400ms and OFF 1600ms) 130KVA/15.6KA
    Power/current at 50% duty cycle(ON 1000ms and OFF 1000ms) 80KVA/9.6KA
    Power/current at 100% duty cycle 50KVA/6KA
    Maximum short-circuit current 38KA
    Flow of cooling water Q ≥8L/min
    Pressure difference of cooling water△P ≥0.15Mpa
    Insulation class H
    Protective grade IP30
    Weight 18KG
    Executive Standard GB/T25301-2021ISO5826:2014
    Contact Us
  • ×
    MF100-68T Welding Transformer

    MF100-68T Welding Transformer

    Power source(U1N) 1000HZ/500V
    Secondary unload voltage(U20) 7.2V
    Power/current at 10% duty cycle(ON 200ms and OFF 1800ms) 160KVA/22KA
    Power/current at 20% duty cycle(ON 400ms and OFF 1600ms) 100KVA/13.6KA
    Power/current at 50% duty cycle(ON 1000ms and OFF 1000ms) 63KVA/8.6KA
    Power/current at 100% duty cycle 40KVA/5.4KA
    Maximum short-circuit current 30KA
    Flow of cooling water Q ≥8L/min
    Pressure difference of cooling water△P ≥0.15Mpa
    Insulation class H
    Protective grade IP30
    Weight 12KG
    Executive Standard GB/T25301-2021ISO5826:2014
    Contact Us
  • ×
    MF80-80T Welding Transformer

    MF80-80T Welding Transformer

    Power source(U1N) 1000HZ/500V
    Secondary unload voltage(U20) 6.3V
    Power/current at 10% duty cycle(ON 200ms and OFF 1800ms) 130KVA/20.5KA
    Power/current at 20% duty cycle(ON 400ms and OFF 1600ms) 80KVA/12.8KA
    Power/current at 50% duty cycle(ON 1000ms and OFF 1000ms) 50KVA/8KA
    Power/current at 100% duty cycle 32KVA/5KA
    Maximum short-circuit current 28KA
    Flow of cooling water Q ≥8L/min
    Pressure difference of cooling water△P ≥0.15Mpa
    Insulation class H
    Protective grade IP30
    Weight 12KG
    Executive Standard GB/T25301-2021ISO5826:2014
    Contact Us
  • ×
    MF160-52T Welding Transformer

    MF160-52T Welding Transformer

    Power source(U1N) 1000HZ/500V
    Secondary unload voltage(U20) 9.6V
    Power/current at 10% duty cycle(ON 200ms and OFF 1800ms) 250KVA/26KA
    Power/current at 20% duty cycle(ON 400ms and OFF 1600ms) 160KVA/16.6KA
    Power/current at 50% duty cycle(ON 1000ms and OFF 1000ms) 100KVA/10.4KA
    Power/current at 100% duty cycle 63KVA/6.5KA
    Maximum short-circuit current 40KA
    Flow of cooling water Q ≥8L/min
    Pressure difference of cooling water△P ≥0.15Mpa
    Insulation class H
    Protective grade IP30
    Weight 18.5KG
    Executive Standard GB/T25301-2021ISO5826:2014
    Contact Us
  • ×
    MF260-38T Welding Transformer

    MF260-38T Welding Transformer

    Power source(U1N) 1000HZ/500V
    Secondary unload voltage(U20) 13.2V
    Power/current at 10% duty cycle(ON 200ms and OFF 1800ms) 400KVA/30KA
    Power/current at 20% duty cycle(ON 400ms and OFF 1600ms) 260KVA/20KA
    Power/current at 50% duty cycle(ON 1000ms and OFF 1000ms) 180KVA/13.7KA
    Power/current at 100% duty cycle 106KVA/8KA
    Maximum short-circuit current 55KA
    Flow of cooling water Q ≥2×8L/min
    Pressure difference of cooling water△P ≥0.15Mpa
    Insulation class H
    Protective grade IP30
    Weight 30KG
    Executive Standard GB/T25301-2021ISO5826:2014
    Contact Us
  • ×
    1000J-450V Capacitor Discharge Welding Transformer

    1000J-450V Capacitor Discharge Welding Transformer

     Product Parameters (1000J)
    Rated Voltage 450V
    NO. of turns 50 turns
    Capacitor 10000UF
    In the case of the secondary loop 400*300mm, rated voltage and capacitor, the effective value of alternating discharge 20KA
    Consumer of cooling water 2L/min
    Insulation class F
    Protective grade II
    Weight 45KG
    Contact Us